Case 1:
A comparison between information according to the manufacturer’s data sheet and the test results of “Tensile performance and cable bending under tension” (operational and installation conditions, under tension, with fixed S-shaped deflecting bends.
Cable properties according to the data sheet and in reality
Data sheets that quote IEC / DIN EN standards give the impression of high reliability
Max. number of fibres |
|
| up to 48 |
Outer diameter | [mm] |
| 11,0 + 0,5 |
Weight | [kg/km] |
| 84 |
Min. bending radius | [mm] | Without tension | 15 x D |
Max. tensile strength | [N] | After installation | 5000 |
Max. lateral pressure | [N] | After installation | 2000 |