News archive

FO 00.02-2 Cable properties

Created by M. Wolf |

Case 2:
Fault analysis of Case 1 fibre breakage:
Is the installation process or the manufacturer to blame?


Cable properties according to the data sheet and in reality
Data sheets that quote IEC / DIN EN standards give the impression of high reliability.

  • Test results for tensile strength, cable bending under tension and lateral pressure after pragmatic testing under installation conditions over S-shaped corner rollers for underground cables
  • Standard requirements for external optical cables acc. to DIN EN 60794-3 and 60794-3-10 (2002)

 

Mechanical properties according to the manufacturer:

Max. number of fibres

 

 

up to 48

Outer diameter

[mm]

 

11,0 + 0,5

Weight

[kg/km]

 

84

Min. bending radius

[mm]

Without tension
With tension

15 x D
20 x D

Max. tensile strength

[N]

After installation
For a short period

5000
6000

Max. lateral pressure

[N]

After installation
For a short period

2000

                                       